Chinese Journal of Oral Implantology ›› 2021, Vol. 26 ›› Issue (2): 129-134.DOI: 10.12337/zgkqzzxzz.2021.04.010
• Case Reports • Previous Articles Next Articles
Feng Lan1,2, Gu Xinhua1
Received:
2021-03-17
Online:
2021-04-10
Published:
2021-07-14
Contact:
Gu Xinhua, Email:guxh@zju.edu.cn, Tel: 0086-571-87236338
Feng Lan, Gu Xinhua. Research progress on imaging evaluation methods of bone mineral density before immediate implant restoration[J]. Chinese Journal of Oral Implantology, 2021, 26(2): 129-134.
Add to citation manager EndNote|Ris|BibTeX
URL: https://zgkqzzxzz.cndent.com/EN/10.12337/zgkqzzxzz.2021.04.010
[1] Van Dessel J, Nicolielo LF, Huang Y, et al.Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT[J]. Eur J Oral Implantol, 2017,10(1):95-105. [2] Guang M, Huang B, Yao Y, et al.Effects of vascular endothelial growth factor on osteoblasts around dental implants in vitro and in vivo[J]. J Oral Sci, 2017,59(2):215-223. DOI: 10.2334/josnusd.16-0406. [3] De Bruyn H, Raes S, Ostman PO, et al.Immediate loading in partially and completely edentulous jaws: a review of the literature with clinical guidelines[J]. Periodontol 2000, 2014,66(1):153-187. DOI: 10.1111/prd.12040. [4] Shaw N, Crabtree N.Bone density in children: what are we measuring?[J]. Arch Dis Child, 2019,104(11):1108-1111. DOI: 10.1136/archdischild-2019-316940. [5] Chugh NK, Bhattacharyya J, Das S, et al.Use of digital panoramic radiology in presurgical implant treatment planning to accurately assess bone density[J]. J Prosthet Dent, 2016,116(2):200-205.e1. DOI: 10.1016/j.prosdent.2016.01.017. [6] Parsa A, Ibrahim N, Hassan B, et al.Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT[J]. Clin Oral Implants Res, 2015,26(1):e1-7. DOI: 10.1111/clr.12315. [7] Tsai MT, He RT, Huang HL, et al.Effect of Scanning Resolution on the Prediction of Trabecular Bone Microarchitectures Using Dental Cone Beam Computed Tomography[J]. Diagnostics (Basel), 2020,10(6). DOI: 10.3390/diagnostics10060368. [8] Min CK, Kim KA.Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study[J]. Dentomaxillofac Radiol, 2021,50(3):20200365. DOI: 10.1259/dmfr.20200365. [9] Messina C, Maffi G, Vitale JA, et al.Diagnostic imaging of osteoporosis and sarcopenia: a narrative review[J]. Quant Imaging Med Surg, 2018,8(1):86-99. DOI: 10.21037/qims.2018.01.01. [10] Mendes MM, Darling AL, Hart KH, et al.Impact of high latitude, urban living and ethnicity on 25-hydroxyvitamin D status: A need for multidisciplinary action?[J]. J Steroid Biochem Mol Biol, 2019,188:95-102. DOI: 10.1016/j.jsbmb.2018.12.012. [11] Wong CP, Gani LU, Chong LR.Dual-energy X-ray absorptiometry bone densitometry and pitfalls in the assessment of osteoporosis: a primer for the practicing clinician[J]. Arch Osteoporos, 2020,15(1):135. DOI: 10.1007/s11657-020-00808-2. [12] Organization W H.WHO Scientific Group on The Assessment of Osteoporosis at Primary Health Care Level[J]. 2004. [13] Shokri A, Ghanbari M, Maleki FH, et al.Relationship of gray values in cone beam computed tomography and bone mineral density obtained by dual energy X-ray absorptiometry[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2019,128(3):319-331. DOI: 10.1016/j.oooo.2019.04.017. [14] Shevroja E, Lamy O, Kohlmeier L, et al.Use of Trabecular Bone Score (TBS) as a Complementary Approach to Dual-energy X-ray Absorptiometry (DXA) for Fracture Risk Assessment in Clinical Practice[J]. J Clin Densitom, 2017,20(3):334-345. DOI: 10.1016/j.jocd.2017.06.019. [15] Jain RK, Vokes T.Dual-energy X-ray Absorptiometry[J]. J Clin Densitom, 2017,20(3):291-303. DOI: 10.1016/j.jocd.2017.06.014. [16] Misch, Carl, E.Contemporary Implant Dentistry[J]. Implant Dentistry, 1999,8(1):1-90. DOI:10.1097/00008505-199901000-00012 [17] Singh SV, Aggarwal H, Gupta V, et al.Measurements in Mandibular Pantomographic X-rays and Relation to Skeletal Mineral Densitometric Values[J]. J Clin Densitom, 2016,19(2):255-261. DOI: 10.1016/j.jocd.2015.03.004. [18] Hwang JJ, Lee JH, Han SS, et al.Strut analysis for osteoporosis detection model using dental panoramic radiography[J]. Dentomaxillofac Radiol, 2017,46(7):20170006. DOI: 10.1259/dmfr.20170006. [19] Kato CN, Barra SG, Tavares NP, et al.Use of fractal analysis in dental images: a systematic review[J]. Dentomaxillofac Radiol, 2020,49(2):20180457. DOI: 10.1259/dmfr.20180457. [20] Vadiati Saberi B, Khosravifard N, Nooshmand K, et al.Fractal analysis of the trabecular bone pattern in the presence/absence of metal artifact-producing objects: Comparison of cone-beam computed tomography with panoramic and periapical radiography[J]. Dentomaxillofac Radiol, 2021:20200559. DOI: 10.1259/dmfr.20200559. [21] Oliveira MR, Gonçalves A, Gabrielli M, et al.Radiographic Evaluation in the Diagnosis of Alveolar Bone Quality in Implant Rehabilitation[J]. J Craniofac Surg, 2020,31(6):1805-1808. DOI: 10.1097/SCS.0000000000006755. [22] Fu MW, Shen EC, Fu E, et al.Assessing Bone Type of Implant Recipient Sites by Stereomicroscopic Observation of Bone Core Specimens: A Comparison With the Assessment Using Dental Radiography[J]. J Periodontol, 2017,88(6):593-601. DOI: 10.1902/jop.2017.160446. [23] Bouxsein ML, Boyd SK, Christiansen BA, et al.Guidelines for assessment of bone microstructure in rodents using micro-computed tomography[J]. J Bone Miner Res, 2010,25(7):1468-1486. DOI: 10.1002/jbmr.141. [24] Kim DG, Christopherson GT, Dong XN, et al.The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone[J]. Bone, 2004,35(6):1375-1382. DOI: 10.1016/j.bone.2004.09.007. [25] Van Dessel J, Nicolielo LF, Huang Y, et al.Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles[J]. Eur J Oral Implantol, 2016,9(4):411-424. [26] Kim JE, Yi WJ, Heo MS, et al.Three-dimensional evaluation of human jaw bone microarchitecture: correlation between the microarchitectural parameters of cone beam computed tomography and micro-computer tomography[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2015,120(6):762-770. DOI: 10.1016/j.oooo.2015.08.022. [27] Guerra E, Almeida FT, Bezerra FV, et al.Capability of CBCT to identify patients with low bone mineral density: a systematic review[J]. Dentomaxillofac Radiol, 2017,46(8):20160475. DOI: 10.1259/dmfr.20160475. [28] Kato CN, Tavares NP, Barra SG, et al.Digital panoramic radiography and cone-beam CT as ancillary tools to detect low bone mineral density in post-menopausal women[J]. Dentomaxillofac Radiol, 2019,48(2):20180254. DOI: 10.1259/dmfr.20180254. [29] Taguchi A, Tsuda M, Ohtsuka M, et al.Use of dental panoramic radiographs in identifying younger postmenopausal women with osteoporosis[J]. Osteoporos Int, 2006,17(3):387-394. DOI: 10.1007/s00198-005-2029-7. [30] Brasileiro CB, Chalub L, Abreu M, et al.Use of cone beam computed tomography in identifying postmenopausal women with osteoporosis[J]. Arch Osteoporos, 2017,12(1):26. DOI: 10.1007/s11657-017-0314-7. [31] de Castro J, Carvalho BF, de Melo NS, et al.A new cone-beam computed tomography-driven index for osteoporosis prediction[J]. Clin Oral Investig, 2020,24(9):3193-3202. DOI: 10.1007/s00784-019-03193-4. [32] Ibrahim N, Parsa A, Hassan B, et al.The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible[J]. Dentomaxillofac Radiol, 2013,42(10):20130206. DOI: 10.1259/dmfr.20130206. [33] Klintström E, Smedby O, Klintström B, et al.Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT[J]. Dentomaxillofac Radiol, 2014,43(8):20140196. DOI: 10.1259/dmfr.20140196. [34] Sennerby L, Andersson P, Pagliani L, et al.Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability[J]. Clin Implant Dent Relat Res, 2015,17(5):844-853. DOI: 10.1111/cid.12193. [35] Zhang Y, Yang J, Zhang L, et al.Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion[J]. Comput Med Imaging Graph, 2015,40:30-38. DOI: 10.1016/j.compmedimag.2014.10.007. [36] Hsu JT, Fuh LJ, Tu MG, et al.The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models[J]. Clin Implant Dent Relat Res, 2013,15(2):251-261. DOI: 10.1111/j.1708-8208.2011.00349.x. [37] Sugiura T, Yamamoto K, Horita S, et al.The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis[J]. J Periodontal Implant Sci, 2016,46(3):152-165. DOI: 10.5051/jpis.2016.46.3.152. [38] Di Stefano DA, Arosio P.Correlation Between Bone Density and Instantaneous Torque at Implant Site Preparation: A Validation on Polyurethane Foam Blocks of a Device Assessing Density of Jawbones[J]. Int J Oral Maxillofac Implants, 2016,31(5):e128-135. DOI: 10.11607/jomi.4475. [39] Irandoust S, Müftü S.The interplay between bone healing and remodeling around dental implants[J]. Sci Rep, 2020,10(1):4335. DOI: 10.1038/s41598-020-60735-7. [40] Cha JY, Pereira MD, Smith AA, et al.Multiscale analyses of the bone-implant interface[J]. J Dent Res, 2015,94(3):482-490. DOI: 10.1177/0022034514566029. [41] Norton MR.The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study[J]. Int J Oral Maxillofac Implants, 2017,32(4):849-857. DOI: 10.11607/jomi.5889. [42] Arsan B, Yalcin-Ülker GM, Meral DG, et al.Is there any predictive bone parameter for implant stability in 2-dimensional and 3-dimensional radiologic images?[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2021,131(3):371-379. DOI: 10.1016/j.oooo.2020.08.009. [43] Suer BT, Yaman Z, Buyuksarac B.Correlation of Fractal Dimension Values with Implant Insertion Torque and Resonance Frequency Values at Implant Recipient Sites[J]. Int J Oral Maxillofac Implants, 2016,31(1):55-62. DOI: 10.11607/jomi.3965. [44] Cortes AR, Eimar H, Barbosa Jde S, et al.Sensitivity and specificity of radiographic methods for predicting insertion torque of dental implants[J]. J Periodontol, 2015,86(5):646-655. DOI: 10.1902/jop.2015.140584. [45] Arsan B, Yalcin-Ülker GM, Meral DG, et al.Is there any predictive bone parameter for implant stability in 2-dimensional and 3-dimensional radiologic images?[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2021,131(3):371-379. DOI: 10.1016/j.oooo.2020.08.009. [46] Attanasio S, Forte SM, Restante G, et al.Artificial intelligence, radiomics and other horizons in body composition assessment[J]. Quant Imaging Med Surg, 2020,10(8):1650-1660. DOI: 10.21037/qims.2020.03.10. [47] Lohmann P, Elahmadawy MA, Gutsche R, et al.FET PET Radiomics for Differentiating Pseudoprogression from Early Tumor Progression in Glioma Patients Post-Chemoradiation[J]. Cancers (Basel), 2020,12(12). DOI: 10.3390/cancers12123835. |
[1] | Li Xiaoyu, He Jie, Wang Xueke, Duan Jingyi, Ge Chang, Meng Weiyan. Application of Bio-Oss Collagen with tent pole procedure in vertical bone augmentation of edentulous maxillary posterior area: a case report [J]. Chinese Journal of Oral Implantology, 2023, 28(2): 97-101. |
[2] | Yang Dezhao, Xu Yingjie, Tang Zhengting, Ma Yuxiao, Li Guangcheng, Meng Fanwen. Application of lag screw technique in alveolar bone block grafting [J]. Chinese Journal of Oral Implantology, 2022, 27(4): 217-223. |
[3] | Su Tianyue, Teng Weiwei, Wang Qi, Shu Qianyi, Zhou Libo. Progress in evaluation methods of dental implant placement accuracy [J]. Chinese Journal of Oral Implantology, 2022, 27(4): 248-253. |
[4] | Cao Xiaojun, Wang Lijie, Wang Tong, Li Jiahe, Zhou Wenjuan, Liu Zhonghao. Study on the influence of alveolar bone density on the long-term stability of dental implants in middle-aged and elderly patients [J]. Chinese Journal of Oral Implantology, 2021, 26(6): 376-381. |
[5] | Li Shufen, Wei Bin. Research progress on registration technology of digital impression and CBCT [J]. Chinese Journal of Oral Implantology, 2021, 26(6): 405-410. |
[6] | Deng Lei, Huang Haitao. Research progress of grafting marterials in maxillary sinus floor elevation [J]. Chinese Journal of Oral Implantology, 2021, 26(3): 192-195. |
[7] | Li Xiaoyu, Cai Qing, Yin Zhaoyi, Jin Zhuohua, Wang Zixuan, Meng Weiyan. Research progress of immune cells in the process osseointegration [J]. Chinese Journal of Oral Implantology, 2021, 26(3): 196-201. |
[8] | CHEN Ping, YAO Guiliang, WANG Xiaheng. The retrospective analysis of a short-term clinical and radiologic applications of kangsheng implants [J]. Chinese Journal of Oral Implantology, 2020, 25(2): 55-59. |
[9] | LI Jun, ZHANG Junhua, SUN Lihua, et al. A retrospective study of locator implant overdenture in elderly edentulous patients [J]. Chinese Journal of Oral Implantology, 2020, 25(2): 64-68. |
[10] | XIAO Ting, LONG Hui, HU Bai, et al. Clinical application about two-stage closed sinus lift combined with CGF for severe bone deficiency in the posterior maxillary [J]. Chinese Journal of Oral Implantology, 2020, 25(2): 76-79. |
[11] | LIN Yong, HOU Dang, CHANG Xiaorong. Application of Onlay bone grafting technique in the dental aesthetic area of anterior teeth [J]. Chinese Journal of Oral Implantology, 2020, 25(1): 4-7. |
[12] | SUN Chenyu, ZHU Hongguang, BAI Jianwen. Cause analysis of dental implant failure [J]. Chinese Journal of Oral Implantology, 2019, 24(3): 139-141. |
[13] | SHI Hairui, KONG Yihua, WNAG Xianhe, et al. Analysis on the changes of CD3+、CD4+、CD8+、IL-2、IL-6 and TNF-α levels in patients with recurrent oral ulcer treated with dental implants [J]. Chinese Journal of Oral Implantology, 2019, 24(2): 55-58. |
[14] | WANG Liang, ZHAN Mengjun, ZHAO Jialong, et al. Age estimation in Sichuan Han female adults based on tooth volume analysis using cone-beam computed tomography [J]. Chinese Journal of Oral Implantology, 2019, 24(1): 5-9. |
[15] | HUANG Lijuan, MU Yandong, QING Wei, et al. Analysis of factors related to early failure after implant implantation [J]. Chinese Journal of Oral Implantology, 2018, 23(3): 131-135. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||