Chinese Journal of Oral Implantology ›› 2024, Vol. 29 ›› Issue (2): 159-168.DOI: 10.12337/zgkqzzxzz.2024.04.011
• Original Article·Basic Research • Previous Articles Next Articles
Wang Qi1, Yang Bo1, Liu Lu1, Li Cuiying1,2, Wang Xinyu1
Received:
2024-01-04
Online:
2024-04-30
Published:
2024-05-08
Contact:
Li Cuiying, Email: licuiying_67@163.com, Tel:0086-10-66014546; Wang Xinyu, Email: wangxinyu@jmsu.edu.cn, Tel: 0086-454-8625654
Wang Qi, Yang Bo, Liu Lu, Li Cuiying, Wang Xinyu. Finite element analysis of the effect of implant design on stress distribution at the bone interface for different jaw densities[J]. Chinese Journal of Oral Implantology, 2024, 29(2): 159-168.
Add to citation manager EndNote|Ris|BibTeX
URL: https://zgkqzzxzz.cndent.com/EN/10.12337/zgkqzzxzz.2024.04.011
[1] Rabel A, Köhler SG, Schmidt-Westhausen AM.Clinical study on the primary stability of two dental implant systems with resonance frequency analysis[J]. Clin Oral Investig, 2007,11(3):257-265. DOI: 10.1007/s00784-007-0115-2. [2] Akça K, Chang TL, Tekdemir I, et al.Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis[J]. Clin Oral Implants Res, 2006,17(4):465-472. DOI: 10.1111/j.1600-0501.2006.01265.x. [3] Ganeles J, Wismeijer D. Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications[J]. Int J Oral Maxillofac Implants, 2004,19 Suppl:92-102. [4] Meredith N.Assessment of implant stability as a prognostic determinant[J]. Int J Prosthodont, 1998,11(5):491-501. [5] Traini T, Assenza B, San RF, et al.Bone microvascular pattern around loaded dental implants in a canine model[J]. Clin Oral Investig, 2006,10(2):151-156.DOI: 10.1007/s00784-006-0043-6. [6] Prabhu N, Naik N, Patil V, et al.A study on effect of geometric patterns and material onstress distribution in dental implant system: a 3-dimensional finite element analysis[J]. Int J Mechanic Product, 2019,9(5):743-752. [7] Lekholm U.Patients selection and preparation. Brånemark, P-I[J].Tissue Integrated Prosthesis Osseointegration in Clinical Dentistry, 1985. [8] Jaffin RA, Berman CL.The excessive loss of Brånemark fixtures in type IV bone: a 5-year analysis[J].J Periodontol, 1991,62(1):2-4.DOI:10.1902/jop.1991.62.1.2. [9] Pattijn V, Van Lierde C, Van der Perre G, et al. The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour. A numerical approach[J]. J Biomech, 2006,39(5):939-947.DOI:10.1016/j.jbiomech.2005.01.035. [10] Eraslan O, Inan O.The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis[J]. Clin Oral Investig, 2010,14(4):411-416. DOI: 10.1007/s00784-009-0305-1. [11] Pegoretti A, Fambri L, Zappini G, et al.Finite element analysis of a glass fibre reinforced composite endodontic post[J]. Biomaterials, 2002,23(13):2667-2682. DOI: 10.1016/s0142-9612(01)00407-0. [12] Pierrisnard L, Bohin F, Renault P, et al.Corono-radicular reconstruction of pulpless teeth: a mechanical study using finite element analysis[J]. J Prosthet Dent, 2002,88(4):442-448. DOI: 10.1067/mpr.2002.128376. [13] Mellal A, Wiskott HW, Botsis J, et al.Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data[J]. Clin Oral Implants Res, 2004,15(2):239-248. DOI: 10.1111/j.1600-0501.2004.01000.x. [14] 皮昕. 口腔解剖生理学[M]. 北京:人民卫生出版社, 2005. [15] John J, Rangarajan V, Savadi RC, et al.A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment[J]. J Indian Prosthodont Soc, 2012,12(1):37-44. DOI: 10.1007/s13191-012-0114-0. [16] Chung SH, Heo SJ, Koak JY, et al.Effects of implant geometry and surface treatment on osseointegration after functional loading: a dog study[J]. J Oral Rehabil, 2008,35(3):229-236. DOI: 10.1111/j.1365-2842.2006.01653.x. [17] Steigenga JT, al-Shammari KF, Nociti FH, et al. Dental implant design and its relationship to long-term implant success[J]. Implant Dent, 2003,12(4):306-317. DOI: 10.1097/01.id.0000091140.76130.a1. [18] Ma P, Liu HC, Li DH, et al.Influence of helix angle and density on primary stability of immediately loaded dental implants: three-dimensional finite element analysis[J]. Zhonghua Kou Qiang Yi Xue Za Zhi, 2007,42(10):618-621.DOI: 10.3760/J-jssn:1002-0098.2007.10.013. [19] Motoyoshi M, Yano S, Tsuruoka T, et al.Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis[J]. Clin Oral Implants Res, 2005,16(4):480-485.DOI:10.1111/j.1600-0501.2005.01130.x. [20] Chun HJ, Cheong SY, Han JH, et al.Evaluation of design parameters of osseointegrated dental implants using finite element analysis[J]. J Oral Rehabil, 2002,29(6):565-574.DOI:10.1046/j.1365-2842.2002.00891.x. [21] Kong L, Liu BL, Hu KJ, et al.Optimized thread pitch design and stress analysis of the cylinder screwed dental implant[J]. Hua Xi Kou Qiang Yi Xue Za Zhi, 2006,24(6):509-512, 515. [22] Liang DK, Wang JH, Ma QS, et al.The influence of the screw thread and the height of constraints on the stress distribution around dental implants by using three-dimensional finite element analysis[J]. Shanghai Kou Qiang Yi Xue, 2002,11(4):324-326. [23] 林野. 当代牙种植体设计进步与临床意义[J].华西口腔医学杂志, 2017,35(1):18-28. DOI: 10.7518/hxkq.2017.01.003. [24] Sakoh J, Wahlmann U, Stender E, et al.Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro[J]. Int J Oral Maxillofac Implants, 2006,21(4):560-566.DOI:10.1016/j.ijom.2006.02.021. [25] Kan JY, Roe P, Rungcharassaeng K.Effects of implant morphology on rotational stability during immediate implant placement in the esthetic zone[J]. Int J Oral Maxillofac Implants, 2015,30(3):667-670. DOI: 10.11607/jomi.3885. [26] Wu SW, Lee CC, Fu PY, et al.The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants[J]. Med Eng Phys, 2012,34(7):797-805. DOI: 10.1016/j.medengphy.2011.09.021. [27] Drago CJ, Del Castillo RA.A retrospective analysis of osseotite NT implants in clinical practice: 1-year follow-up[J]. Int J Periodontics Restorative Dent, 2006,26(4):337-345. [28] Kim JW, Baek SH, Kim TW, et al.Comparison of stability between cylindrical and conical type mini-implants. Mechanical and histological properties[J]. Angle Orthod,2008,78(4):692-698.DOI: 10.2319/0003-3219(2008)078[0692:COSBCA]2.0.CO;2. [29] Siegele D, Soltesz U.Numerical investigations of the influence of implant shape on stress distribution in the jaw bone[J]. Int J Oral Maxillofac Implants, 1989,4(4):333-340. [30] Al-Nawas B, Wagner W, Grötz KA.Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants[J]. Int J Oral Maxillofac Implants, 2006,21(5):726-732. [31] Toyoshima T, Wagner W, Klein MO, et al.Primary stability of a hybrid self-tapping implant compared to a cylindrical non-self-tapping implant with respect to drilling protocols in an ex vivo model[J]. Clin Implant Dent Relat Res, 2011,13(1):71-78.DOI:10.1111/j.1708-8208.2009.00185.x. [32] Chong L, Khocht A, Suzuki JB, et al.Effect of implant design on initial stability of tapered implants[J]. J Oral Implantol, 2009,35(3):130-135. DOI: 10.1563/1548-1336-35.3.130. [33] Meijer HJ, Kuiper JH, Starmans FJ, et al.Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible[J]. J Prosthet Dent, 1992,68(1):96-102. DOI: 10.1016/0022-3913(92)90293-j. |
[1] | Yang Bo, Man Yi. Application of bone substitutes in the incisive canal for implant placement [J]. Chinese Journal of Oral Implantology, 2023, 28(5): 315-319. |
[2] | Zhang Xiaohan, Lv Mingyue, Zhang Shiwen, Yuan Quan. Selection of bone graft materials in vertical bone augmentation surgery [J]. Chinese Journal of Oral Implantology, 2023, 28(5): 320-326. |
[3] | Li Xiaojing, Liu Ran, Zhen Li, Mei Dongmei, Liu Zhao, Li Fan, Xu Hao, Teng Minhua, Wang Dashan, Zhao Baodong. Exploration of ideological and political education in undergraduate teaching of dental implantology [J]. Chinese Journal of Oral Implantology, 2023, 28(5): 383-386. |
[4] | Su Tianyue, Zhao Jinrong, Teng weiwei, Liu Penghui, Li Xinru, Zhou Libo. An in vitro study on the comparison of implant accuracy of freehand, implant surgical guide, and dental implant robot [J]. Chinese Journal of Oral Implantology, 2023, 28(4): 244-249. |
[5] | Xu Shulan, Li Ping. Robotic computer-assisted implant surgery: opportunities and challenges [J]. Chinese Journal of Oral Implantology, 2023, 28(3): 140-145. |
[6] | Xie Rui, Li Zhiwen, Ren Nan, Zhao Ruifeng, Bai Shizhu. Study on the surgical accuracy of dental implant robot with different optical tracking systems [J]. Chinese Journal of Oral Implantology, 2023, 28(3): 152-158. |
[7] | He Jin, Ren Lingfei, Zhang Qinmeng, Jiang Zhiwei, Yang Guoli. Analysis of the clinical application value of minimally invasive non-flap technique based on autonomous robot implant surgery [J]. Chinese Journal of Oral Implantology, 2023, 28(3): 159-164. |
[8] | Ma Rui, Wang Zhihui, LiuYang, Gao Yang. Force analysis of personalized titanium mesh for guided bone regeneration based on finite element method [J]. Chinese Journal of Oral Implantology, 2023, 28(3): 198-203. |
[9] | Fu Li, Xu Yanxue, Wang Lin. Tentative exploration of “ideological and political education” in oral implantology course [J]. Chinese Journal of Oral Implantology, 2022, 27(3): 188-192. |
[10] | Liu Chengwu, Liu Yuanxiang, Li Zhipeng, Liu Quan, Wu Shiyu, Wu Xiayi, Chen Zetao, Huang Baoxin, Chen Zhuofan. The effects of different thread designs on osseointegration of dental implants: a comparative experimental study in canine jaw [J]. Chinese Journal of Oral Implantology, 2021, 26(4): 226-231. |
[11] | Chinese Society of Oral Implantology. Summary of the 12th national conference on oral implantology [J]. Chinese Journal of Oral Implantology, 2021, 26(4): 264-274. |
[12] | ZHANG Jie, XIA Chuanchu, LI Xiaoping. The clinical application of platelet-rich fibrin(PRF)combined with artificial bone meal in oral implant guided bone regeneration [J]. Chinese Journal of Oral Implantology, 2020, 25(4): 165-168. |
[13] | WANG Lele. The application effect of fine nursing in the continuous disinfection of circulating air in the dental implant operation room [J]. Chinese Journal of Oral Implantology, 2020, 25(4): 180-181. |
[14] | NI Kezhou, CHENG Xueyun. Analysis of the application value of minimally invasive non-flap technique in oral implantation [J]. Chinese Journal of Oral Implantology, 2020, 25(3): 134-136. |
[15] | PENG Guixue. Evaluate of the implementation value of standard operating procedures in planting care coordination [J]. Chinese Journal of Oral Implantology, 2019, 24(4): 184-186. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||