[1] Zafiropoulos GG, Abuzayeda M, Al-Asfour AA, et al.Tooth-implant connection with fixed partial dentures in partially edentulous arches. A retrospective cohort study over an 11.8 year observation period[J]. J Clin Exp Dent, 2021, 13(7):e659-e668. DOI: 10.4317/jced.58170. [2] Sharma AJ, Nagrath R, Lahori M.A comparative evaluation of chewing efficiency, masticatory bite force, and patient satisfaction between conventional denture and implant-supported mandibular overdenture: an in vivo study[J]. J Indian Prosthodont Soc, 2017, 17(4):361-372. DOI: 10.4103/jips.jips_76_17. [3] López CS, Saka CH, Rada G, et al.Impact of fixed implant supported prostheses in edentulous patients: protocol for a systematic review[J]. BMJ Open, 2016, 6(2):e009288. DOI: 10.1136/bmjopen-2015-009288. [4] Gibbard LL, Zarb G.A 5-year prospective study of implant-supported single-tooth replacements[J]. J Can Dent Assoc, 2002, 68(2):110-116. [5] Dörfer CE, von Bethlenfalvy ER, Staehle HJ, et al. Factors influencing proximal dental contact strengths[J]. Eur J Oral Sci, 2000, 108(5):368-377. DOI: 10.1034/j.1600-0722.2000.108005368.x. [6] Saber A, Chakar C, Mokbel N, et al.Prevalence of interproximal contact loss between implant-supported fixed prostheses and adjacent teeth and its impact on marginal bone loss: a retrospective study[J]. Int J Oral Maxillofac Implants, 2020, 35(3):625-630. DOI: 10.11607/jomi.7926. [7] Ren S, Lin Y, Hu X, et al.Changes in proximal contact tightness between fixed implant prostheses and adjacent teeth: a 1-year prospective study[J]. J Prosthet Dent, 2016, 115(4): 437-440. DOI: 10.1016/j.prosdent.2015. 08.018. [8] Pang NS, Suh CS, Kim KD, et al.Prevalence of proximal contact loss between implant-supported fixed prostheses and adjacent natural teeth and its associated factors: a 7-year prospective study[J]. Clin Oral Implants Res, 2017, 28(12):1501-1508. DOI: 10.1111/clr.13018. [9] d'Incau E, Couture C, Maureille B. Human tooth wear in the past and the present: tribological mechanisms, scoring systems, dental and skeletal compensations[J]. Arch Oral Biol, 2012, 57(3):214-229. DOI: 10.1016/j.archoralbio. 2011.08.021. [10] Thilander B, Odman J, Jemt T.Single implants in the upper incisor region and their relationship to the adjacent teeth. An 8-year follow-up study[J]. Clin Oral Implants Res, 1999, 10(5): 346-355. DOI:10.1034/j.1600-0501.1999.100502.x. [11] Chang M, Wennström JL.Longitudinal changes in tooth/single-implant relationship and bone topography: an 8-year retrospective analysis[J]. Clin Implant Dent Relat Res, 2012, 14(3):388-394. DOI: 10.1111/j.1708-8208.2010.00272.x. [12] Wei H, Tomotake Y, Nagao K, et al.Implant prostheses and adjacent tooth migration: preliminary retrospective survey using 3-dimensional occlusal analysis[J]. Int J Prosthodont, 2008, 21(4):302-304. [13] Oh WS, Oh J, Valcanaia AJ.Open proximal contact with Implant-supported fixed prostheses compared with tooth-supported fixed prostheses: a systematic review and meta-analysis[J]. Int J Oral Maxillofac Implants, 2020, 30(6):e99-e108. DOI: 10.11607/jomi.8415. [14] Varthis S, Randi A, Tarnow DP.Prevalence of interproximal open contacts between single-implant restorations and adjacent teeth[J]. Int J Oral Maxillofac Implants, 2016, 31(5):1089-1092. DOI: 10.11607/jomi.4432. [15] Yen JY, Kang L, Chou IC, et al.Risk assessment of interproximal contact loss between implant-supported fixed prostheses and adjacent teeth: a retrospective radiographic study[J]. J Prosthet Dent, 2022, 127(1):86-92. DOI: 10.1016/j.prosdent.2020.06.023. [16] Byun S J, Heo S M, Ahn S G, et al.Analysis of proximal contact loss between implant-supported fixed dental prostheses and adjacent teeth in relation to influential factors and effects. A cross-sectional study[J]. Clin Oral Implants Res, 2015, 26(6): 709-714.DOI:10.1111/clr.12373. [17] Wong AT, Wat PY, Pow EH, et al.Proximal contact loss between implant-supported prostheses and adjacent natural teeth: a retrospective study[J]. Clin Oral Implants Res, 2015, 26(4):e68-e71. DOI: 10.1111/clr.12353. [18] Jeong J S, Chang M.Food impaction and periodontal/peri-implant tissue conditions in relation to the embrasure dimensions between implant-supported fixed dental prostheses and adjacent teeth: a cross-sectional study[J]. J Periodontol, 2015, 86(12): 1314-1320.10.1902/jop.2015.150322. [19] Papandreas SG, Buschang PH, Alexander RG, et al.Physiologic drift of the mandibular dentition following first premolar extractions[J]. Angle Orthod, 1993, 63(2):127-134. DOI:10.1043/0003-3219(1993)063<0127: PDOTMD>2.0.CO;2. [20] Luo Q, Ding Q, Zhang L, et al.The loss of interproximal contact between posterior fixed implant prostheses and adjacent teeth: a retrospective study[J]. Zhonghua Kou Qiang Yi Xue Za Zhi, 2016, 51(1):15-19. DOI: 10.3760/cma.j.issn.1002-0098.2016.01.005. [21] Lee PK, Siu AS.A two-year evaluation of a sloped marginal contour implant system placed in healed sites[J]. Int J Oral Maxillofac Implants, 2016, 31(6):1423-1428. DOI: 10.11607/jomi.4659. [22] Liang CH, Nien CY, Chen YL, et al.The prevalence and associated factors of proximal contact loss between implant restoration and adjacent tooth after function: a retrospective study[J]. Clin Implant Dent Relat Res, 2020, 22(3):351-358. DOI: 10.1111/cid.12918. [23] Greenstein G, Carpentieri J, Cavallaro J.Open contacts adjacent to dental implant restorations: etiology, incidence, consequences, and correction[J]. J Am Dent Assoc, 2016, 147(1):28-34. DOI: 10.1016/j.adaj.2015.06.011. [24] Abduo J, Lee CL, Sarfarazi G, et al.Encode protocol versus conventional protocol for single-implant restoration: a prospective 2-year follow-up randomized controlled trial[J]. J Oral Implantol, 2021, 47(1):36-43. DOI: 10.1563/aaid -joi-D-19-00150. [25] Bompolaki D, Edmondson SA, Katancik JA.Interproximal contact loss between implant- supported restorations and adjacent natural teeth: a retrospective cross-sectional study of 83 restorations with an up to 10-year follow-up[J]. J Prosthet Dent, 2022, 127(3):418-424. DOI: 10. 1016/j.prosdent.2020.09.034. [26] Rinke S, Ohl S, Ziebolz D, et al.Prevalence of periimplant disease in partially edentulous patients: a practice-based cross-sectional study[J]. Clin Oral Implants Res, 2011, 22(8):826-833. DOI: 10.1111/j.1600-0501.2010.02061.x. [27] Canullo L, Peñarrocha-Oltra D, Covani U, et al.Clinical and microbiological findings in patients with peri-implantitis: a cross-sectional study[J]. Clin Oral Implants Res, 2016, 27(3):376-382. DOI: 10.1111/clr.12557. [28] Davies SJ. Occlusal considerations in implantology: good occlusal practice in implantology[J].Dent Update, 2010, 37(9):610-612, 615-616, 619-620. DOI: 10.12968/denu.2010.37.9.610. [29] Sarig R, Lianopoulos NV, Hershkovitz I, et al.The arrangement of the interproximal interfaces in the human permanent dentition[J]. Clin Oral Investig, 2013, 17(3):731-738. DOI: 10.1007/ s00784-012-0759-4. [30] Koori H, Morimoto K, Tsukiyama Y, et al.Statistical analysis of the diachronic loss of interproximal contact between fixed implant prostheses and adjacent teeth[J]. The Int J Pprosthodont, 2010, 23(6): 535-540. |