1 Santiago Junior J F, Pellizzer E P, Verri F R, et al. Stress analysis in bone tissue around single implants with different diameters and veneering materials: A 3-D finite element study[J]. Materials Science & Engineering C Materials for Biological Applications, 2013, 33(8) : 4700-4714 2 Millen C, Wittneben J G. Influence of Prosthesis Type and Retention Mechanism on Complications with Fixed Implant-Supported Prostheses: A Systematic Review Applying Multivariate Analyses[J]. International Journal of Oral & Maxillofacial Implants, 2014, 30(1) : 110-124 3 Akalin Z F, Ozkan Y K, Ekerim A. Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy[J]. International Journal of Oral & Maxillofacial Implants, 2013, 28(1) : 149-157 4 Liou A D, Nicholls J I, Yuodelis R A, et al. Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials[J]. International Journal of Prosthodontics, 1993, 6(4) : 377 5 Nakhaei M, Madani A S, Moraditalab A, et al. Three-dimensional accuracy of different impression techniques for dental implants[J]. Dental Research Journal, 2015, 12(5) : 431 6 Pujari M, Garg P, Prithviraj D R. Evaluation of accuracy of casts of multiple internal connection implant prosthesis obtained from different impression materials and techniques: an in vitro study[J]. Journal of Oral Implantology, 2014, 40(2) : 137-145 7 Del'Acqua M A, Chávez A M, Compagnoni M A, et al. Accuracy of impression techniques for an implant-supported prosthesis[J]. International Journal of Oral & Maxillofacial Implants, 2010, 25(25) : 715-721 8 Sorrentino R, Gherlone E F, Calesini G, et al. Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study[J]. Clinical Implant Dentistry and Related Research, 2010, 12(supplement) : e63-e76 9 Balouch F, Jalalian E, Nikkheslat M, et al. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants[J]. Journal of Dentistry, 2013, 14(3) : 96-102 10 Zen B M, Soares E F, Rodrigues M A, et al. Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants[J]. Journal of Oral Implantology, 2015, 41(6) 11 Patil R, Kadam P, Oswal C, et al. A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques[J]. Journal of International Society of Preventive & Community Dentistry, 2016, 6(2) : 142 12 Balouch F, Jalalian E, Nikkheslat M, et al. Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants[J]. Journal of Dentistry, 2013, 14(3) : 96-102 13 Papaspyridakos P, Hirayama H, Chen C, et al. Full‐arch implant fixed prostheses: acomparative study on the effect of connection type and impression technique on accuracy of fit[J]. Clinical Oral Implants Research, 2015, 13(3) : 1051-1057 14 Pujari M, Garg P, Prithviraj D R. Evaluation of accuracy of casts of multiple internal connection implant prosthesis obtained from different impression materials and techniques: an in vitro study[J]. Journal of Oral Implantology, 2014, 40(2) : 137-145 15 Faria J C, Silva-Concílio L R, Neves A C, et al. Evaluation of the accuracy of different transfer impression techniques for multiple implants[J]. Braz Oral Res, 2011, 25(2) : 163-167 16 Martínez-Rus F, García C, Santamaría A, et al. Accuracy of definitive casts using 4 implant-level impression techniques in a scenario of multi-implant system with different implant angulations and subgingival alignment levels[J]. Implant dentistry, 2013, 22(3) : 268-276 17 Kim S, Nicholls J I, Han C H, et al. Displacement of implant components from impressions to definitive casts[J]. International Journal of Oral & Maxillofacial Implants, 2006, 21(5) : 747-755 18 Braian M, De B H, Fransson H, et al. Tolerance Measurements on Internal-and External-Hexagon Implants[J]. International Journal of Oral & Maxillofacial Implants, 2014, 29(4) : 846-852 19 Lee S J, Betensky R A, Gianneschi G E, et al. Accuracy of digital versus conventional implant impressions[J]. Clinical Oral Implants Research, 2015, 26(6) : 715-719 20 Papaspyridakos P, Gallucci G O, Chen C J, et al. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes[J]. Clinical Oral Implants Research, 2015, 27(4) : 465-472 21 Giménez B, Ozcan M, Martínezrus F, et al. Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience, implant angulation, and depth[J]. Clinical Implant Dentistry & Related Research, 2015, 17(Supplement S1) : e54-e64 22 Abdelazim T, Zandinejad A, Elathamna E, et al. The influence of digital fabrication options on the accuracy of dental implant-based single units and complete-arch frameworks[J]. International Journal of Oral & Maxillofacial Implants, 2014, 29(6) : págs. 1281-1288 23 Ahlholm P, SipilaK, Vallittu P, et al. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review[J]. Journal of Prosthodontics Official Journal of the American College of Prosthodontists, 2016 24 Flügge T V, Schlager S, Nelson K, et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner[J]. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 2013, 144(3) : 471-478 25 Güth J F, Edelhoff D, Schweiger J, et al. A new method for the evaluation of the accuracy of full-arch digital impressions in vitro[J]. Clinical Oral Investigations, 2016(7) : 1-8 26 Goracci C, Franchi L, Vichi A, et al. Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence[J]. European Journal of Orthodontics, 2016, 275(4) : 191-192 27 Vandeweghe S, Vervack V, Dierens M, et al. Accuracy of digital impressions of multiple dental implants: an invitro study[J]. Clinical Oral Implants Research, 2016 28 Fluegge T, Att W, Metzger M, et al. A Novel Method to Evaluate Precision of Optical Implant Impressions with Commercial Scan Bodies-An Experimental Approach[J]. Journal of Prosthodontics, 2015 29 Giménez B, Ozcan M, Martínezrus F, et al. Accuracy of a Digital Impression System Based on Active Triangulation Technology With Blue Light for Implants: Effect of Clinically Relevant Parameters[J]. Implant Dentistry, 2015, 24(5) : 498-504 30 Flügge T V, Schlager S, Nelson K, et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner[J]. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 2013, 144(3) : 471-8 31 Ehsani S, Siadat H, Alikhasi M. Comparative evaluation of impression accuracy of tilted and straight implants in All-on-Four technique[J]. Implant dentistry, 2014, 23(2) : 225-230 32 Fellow B G D. Accuracy of a Digital Impression System Based on Active Wavefront Sampling Technology for Implants Considering Operator Experience, Implant Angulation, and Depth[J]. Clinical Implant Dentistry and Related Research, 2015, 17(supplement) : e54-e64 33 Humberto Gennari Filho DDS MS PhD, Eduardo Vedovatto DDS MS. Accuracy of Impression Techniques for Impants. Part 2-Comparison of Splinting Techniques[J]. Journal of Prosthodontics Official Journal of the American College of Prosthodontists, 2009, 18(2) : 172-176 34 Sorrentino R, Gherlone E F, Calesini G, et al. Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study[J]. Clinical Implant Dentistry and Related Research, 2010, 12(supplement) : e63-e76 35 Shim J S, Ryu J J, Shin S W, et al. Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions[J]. Implant Dentistry, 2015, 24(6) : 726-729 36 Rutkunas V, Sveikata K, Savickas R.Effects of implant angulation, materialselection, and impression technique onimpression accuracy: A preliminary laboratory study. Int [J] Prosthodont. 2012, 25 : 512-515 37 Jang H K, Kim S, Shim J S, et al. Accuracy of impressions for internal-connection implant prostheses with various divergent angles[J]. International Journal of Oral & Maxillofacial Implants, 2011, 26(5) : 1011-1015 38 Linkevicius T, Svediene O. The influence of implant placement depth and impression material on the stability of an open tray impression coping[J]. Journal of Prosthetic Dentistry, 2012, 108(4) : 238-243 39 Lee H, Ercoli C, Funkenbusch P D, et al. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study[J]. The Journal of Prosthetic Dentistry, 2008, 99(2) : 107-113 40 Dds E B, Shamshiri A R, Marzieh Alikhasi DDS MS, et al. Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments[J]. Journal of Prosthodontics, 2015 |